Working principle: | After the batteries have been assembled they are transferred from the S-rail to the main tower of the tester to check the voltage of the batteries. After measuring the voltage of the battery, the length is checked. The batteries are simultaneously transferred to the weighing tray for weighing by vacuum suction. Unqualified batteries are rejected through the reject port and stored. |
Equipment characteristics: | Feeding method: S-rail, vacuum suction method Testing method: Electrical performance tester, weighing pan Acceptance criteria for batteries aged at 45°C for 48 hours |
Technical specifications: | 600 cells/min |